Corporate Home Page 1-Commercial/Industrial 2-Poultry-Animal 3-Construction/Temporary 4-Garage/Residential
Overview History Executive Profile
Benefits of Infrared Heating Cold Blocker Series Specifications Dimensions Supply Requirements Clearance Info. Accessories
Heater Selection Guide COMPUHEAT Heat Loss Analysis Installation & Operating Instructions (PDF) Submittal Data (PDF) Short Form Specs Troubleshooting Guide (PDF) Sequence of Operations
Garage Clubhouses Enclosed Patio Entryways Greenhouse Workshop Solarium Swimming Pool Area Vestibule Case Studies
Product Answers Company Answers All Other Answers
What's New! Space-Ray E-Newsletters E-Newsletters Sign Up
Request Quote Email Us General Info. Maps Directions
Welcome to Space-Ray - Infrared Gas Heaters
click to contact us
  Infrared Radiant Heating for Garage / Residential Applications

Cold Blocker Series


Specifications | Dimensions | Supply Requirements | Clearance Info. | Accessories


Specifications

Features
  • Four different input sizes from 20,000 to 50,000 Btu/hr
  • Natural or propane gas
  • U-tube design for uniform energy distribution
  • Compact size for easy installation from 6' to 20' above floor.

Radiant Emitter Tube System

  • 3" O.D. calorized aluminized steel emitter tube for long life and high radiant efficiency
  • 5-year limited warranty on the emitter tube
  • Smooth cast iron "U" bend
Vacuum System
  • Products of combustion are pulled through the combustion chamber for increased radiant efficiency and greater safety
  • No draft hoods; totally enclosed combustion chamber

Burner System

  • One-piece cast iron burner
  • 10-year limited warranty on burner
  • Direct outside air for combustion
  • 4" O.D. combustion air intake and vent
  • Direct spark ignition system with step opening gas valve and 100% Gas Shut-Off Safety Control (pre-purge)
  • Monitoring lights for visual diagnosis of maintenance needs

Reflector System

  • Highly efficient aluminum reflectors
  • Reflector ends are enclosed for maximum radiant heat output and minimum convection loss
  • Suitable for horizontal or angle mount up to 45 degrees
Other
  • Lower mounting height kit required on heater installations between 6 and 8 feet
  • Optional deflector kit for reduced clearances to combustible materials
  • Optional decorative grille kit for drop ceiling applications

see Short Form Specs for more detailed information

Cold Blocker Infrared Tube Heater

Cold Blocker with Emitter Guard

CB Series Product Brochure
(PDF)

CB Series Installation &
Operating Instructions

(PDF)

CB Series Submittal
(PDF)

Tube Heater Accessories
(PDF)

< back to top >
Dimensions
 
View Dimensions for Cold Blocker Infrared Radiant Gas Tube Heater
 

MODEL

INPUT
BTU/HR

MINIMUM MOUNTING HEIGHT TOTAL TUBE LENGTH OVERALL DIMENSION

CB20

20,000

8'

15'

9' 3"

CB30

30,000

8'

15'

9' 3"

CB40

40,000

8'

15'

9' 3"

CB50

50,000

8' 15' 9' 3"
 

Supply Requirements

 

 

< back to top >

Clearance Information

 

NOTE: The clearances specified above must be maintained to combustibles and other materials that may be damaged by temperatures 90ºF above ambient temperature. Clearances to combustibles are posted on the reflector near the control end of the heater. In locations used for storage of combustible materials where they may be stacked below the heater, NFPA 54 requires that the installer must post signs that will "specify the maximum permissible stacking height to maintain the required clearances from the heater to combustibles".

 
 

Accessories

Deflector Kit

 
Deflector Kit for CB Infrared Heater
 


Lower Mounting Kit
Lower Mounting Kit for CB Infrared Radiant Gas HeatThe Lower Mounting Kit (Part #43515000) is required when the CB series of infrared tube heaters is installed at mounting heights between 6 ft. and 8 ft. above a finished floor. The Lower Mounting Kit consists of both the Emitter Guard Kit and the Draft Inducer Guard Kit as described below. 

1. Emitter Guard Kit
The Emitter Guard Kit (Part #43485000) includes an aluminum decorative grille with side emitter guard holder panels.  This item and the Draft Inducer Guard Kit make up the Lower Mounting Kit, which must be used in installations with mounting heights between 6 ft. and 8 ft.  This item could be used separately in installations above 8 ft., however, for decorative purposes if desired.


details on Emitter Guard Kit (PDF)


2. Draft Inducer Guard Kit
The Draft Inducer Guard Kit (Part #43486000) is an aluminum shield mounted around the draft inducer (brackets and screws included). 

This item and the Emitter Guard Kit make up the Lower Mounting Kit, which must be used in installations with mounting heights between 6 ft. and 8 ft.

details on Draft Inducer Kit (PDF)

 
< back to top >
 
 
 
< back to top >
 



To request a quote or if you need additional information, please call Space-Ray toll free at 800-438-4936 or send us an email.

Besides this Garage / Residential Infrared gas heating product line, other Space-Ray divisions include: Commercial / Industrial, Poultry & Construction.

| home | about us | products: industrial / poultry / construction / garage | news2use | contact info. | email us | site map |

© 2006 Copyright — Space-Ray, Division of Gas Fired Products, Inc. — Charlotte, North Carolina   USA
International Manufacturer of Infrared Radiant Gas Heaters

 

 